당신은 주제를 찾고 있습니까 “fujikura 70r troubleshooting – Why Do I Have to Do an Arc Calibration on My Fusion Splicer?“? 다음 카테고리의 웹사이트 https://ppa.charoenmotorcycles.com 에서 귀하의 모든 질문에 답변해 드립니다: https://ppa.charoenmotorcycles.com/blog. 바로 아래에서 답을 찾을 수 있습니다. 작성자 Fiber Instrument Sales 이(가) 작성한 기사에는 조회수 44,029회 및 좋아요 192개 개의 좋아요가 있습니다.
fujikura 70r troubleshooting 주제에 대한 동영상 보기
여기에서 이 주제에 대한 비디오를 시청하십시오. 주의 깊게 살펴보고 읽고 있는 내용에 대한 피드백을 제공하세요!
d여기에서 Why Do I Have to Do an Arc Calibration on My Fusion Splicer? – fujikura 70r troubleshooting 주제에 대한 세부정보를 참조하세요
Calibrating your fusion splicer’s arc power, before each splicing session, is a crucial step to ensure proper splices.
www.fiberinstrumentsales.com
fujikura 70r troubleshooting 주제에 대한 자세한 내용은 여기를 참조하세요.
Error Message List – Fujikura 70S Instruction Manual [Page 86]
Follow the solution precisely as shown in the list below. If it is not possible to eliminate the. problem, the splicer may require service by a qualified …
Source: www.manualslib.com
Date Published: 4/26/2022
View: 7130
How to self maintain your Fujikura’s fusion splicer ?
Motor problems; Camera’s focus problem … In order to help you self maintain your Fujikura’s fusion splicer, please find below a veo tutorial showing how …
Source: www.itochu-hightech.com
Date Published: 3/23/2021
View: 1494
Instruction manual – Fiber Instrument Sales
Questions and Troubleshooting . … Fujikura Ltd. gives much conseration and regard to personal injury. Misuse of the machine.
Source: fiberinstrumentsales.com
Date Published: 9/4/2022
View: 745
Fujikura Fusion Splicer
You can count on us for a solution to your every problem. Service & Support: Fusion Splicer must keep good condition as master’s tools to maintain good …
Source: www.fujikura.com
Date Published: 11/28/2021
View: 8494
Coworker keeps getting “fat fiber” error with Fujikura 70R …
Coworker keeps getting “fat fiber” error with Fujikura 70R machine. All maintenance has been performed, electrodes have been replaced.
Source: www.reddit.com
Date Published: 4/23/2021
View: 351
Fiber fusion splicing problem – Wire Association International
While attempting to splice a MM fiber cable we experienced several fiber “separation” faults (the fibers melted away from each other). Our Fujikura 50S …
Source: wirenet.org
Date Published: 9/16/2021
View: 1903
Fujikura 70R Ribbon Splicer Maintenace, Calibration and …
We have been trained for maintenance and repair of the 70R 12 fiber ribbon splicer. If you are in Canada with issues with a Fujikura ribbon splicer, …
Source: simbol.ca
Date Published: 11/17/2021
View: 8057
Fujikura Splicer Cleaning – Calibration – Repair Services
Fujikura Fusion Splicer Calibration | Fujikura Repair | FiberOptic Resales | New and … Preventative maintenance; Annual cleaning; Camera issues …
Source: www.fiberopticresale.com
Date Published: 3/29/2022
View: 1075
주제와 관련된 이미지 fujikura 70r troubleshooting
주제와 관련된 더 많은 사진을 참조하십시오 Why Do I Have to Do an Arc Calibration on My Fusion Splicer?. 댓글에서 더 많은 관련 이미지를 보거나 필요한 경우 더 많은 관련 기사를 볼 수 있습니다.
주제에 대한 기사 평가 fujikura 70r troubleshooting
- Author: Fiber Instrument Sales
- Views: 조회수 44,029회
- Likes: 좋아요 192개
- Date Published: 2017. 2. 2.
- Video Url link: https://www.youtube.com/watch?v=ObFQpUxx3jY
Error Message List – Fujikura 70S Instruction Manual [Page 86]
Press ENT when an error is shown on the monitor. The [HELP] screen displays the following:
・
If error does not have an error code, such as “Cleave Shape NG”, the keystrokes are
displayed with information explaining what each keystroke does if pressed.
・
If error has an error code, additional information according to the Error Code and Message
is displayed.
Follow the solution precisely as shown in the list below. If it is not possible to eliminate the
problem, the splicer may require service by a qualified service center. Consult the authorized
distributor with the following information:
・
Model name of the splicer
・
Serial number of the splicer
・
Error message
・
Error code (if shown)
・
Situation when the error occurs
Error
Reason
Message
L-Too Long
・
The cleave length (bare
Fiber
fiber part) is too long.
R-Too Long
・
Dust or dirt is on the
Fiber
objective lens or the
LR-Too Long
wind-protector mirror.
Fiber
X-Dark
・
Back Ground
Dust or dirt is on the
objective lens or the
Y-Dark
wind-protector mirror.
Back Ground
X-Dark
Back Ground
・
The LED or Camera
might be damaged.
Y-Dark
Back Ground
•
Dust or dirt is on the fiber
L-Too Dusty
surface.
Fiber
•
Dust or dirt is on the
objective lens.
R-Too Dusty
•
[Cleaning Arc] time is tooFiber
short or “OFF.”
Error Message List
Solution
・
Confirm the setting position of the stripped fiber
end on the fiber cleaver. Check the cleave
length.
・
Execute the [Dust Check]. Clean the lens or the
mirror when dust or dirt exists.
・
Execute the [Dust Check]. Clean the lens or the
mirror if dust or dirt exists.
・
Consult the authorized distributor.
•
Completely prepare the fiber again (strip, clean
and cleave).
•
Execute the [Dust Check]. Clean the lens if dust
or dirt exists.
•
Set the [Cleaning Arc] time to “150ms.” When
splicing carbon coated fibers, set to “200ms.”
70S_Rev1
82
How to self maintain your Fujikura’s fusion splicer ?
How to self maintain your Fujikura’s fusion splicer ?
Since 25 years our After Sales service team has maintained and repaired different generations of Fujikura’s fusion splicer. Following the years we have noticed that approximately 25% of the splicers sent back for service were showing a malfuntion only due to a non adaptive or no regular cleaning of the critical parts of the splicer.
These critical parts are the following :
V groove
Clamps and pads
Camera’s focus lens
As the splicer is used, dust or fiber optic waste lay or accumulate on those different parts causing the following problems :
Motor problems
Camera’s focus problem
As soon as too many dust has accumulated on the V groove, fiber optics show an offset too important which prevent the motors to correct the offest and align the fibers. In worst case scenario motors can be blocked on a far end position.
It is then essential to clean regularly these critical parts of the fusion splicer !!!
In order to help you self maintain your Fujikura’s fusion splicer, please find below a video tutorial showing how to clean efficiently your splicer.
Fujikura Fusion Splicer
When talking on the phone or using the internet, our splicers are used to connect optical fibers with superior precision to ensure your data are transmitted reliably anywhere.
Fusion splicers have contributed in telecommunications, medical application, image process, energy research where light matters.
You might have seen the Yellow-Box which is one of Fujikura Splicer’s unique characteristics before.
Fiber fusion splicing problem
Hi, I’m new to this forum and would like to share with you guys a more than somewhat frustrating fiber fusion splicing problem I recently experienced
While attempting to splice a MM fiber cable we experienced several fiber “separation” faults (the fibers melted away from each other).
Our Fujikura 50S Instruction Manual suggested the following causes and remedies:
Fiber stuffing too small – Perform [Motor Calibration]
Prefuse power too high – Decrease [Prefuse Power]
Prefuse time too long – Decrease [Prefuse Time]
After much mental anguish, we eventually (several hours later) discovered that our problem was dirty electrodes. Using a knife, we scraped off the silica oxide buildup from the electrodes, the wiped the electrodes using an alcohol-impregnated lint-free tissue, and then removed the excess alcohol from the electrodes. We then managed to complete our splicing without any obvious effort!
Has this happened to anyone else?
Joe – SA
Fujikura 70R Ribbon Splicer Maintenace, Calibration and Repair
Simbol Test Systems has been America Fujikura Ltd (AFL) service center for Canada for over 10 years. Simbol’s specialized technicians are trained by AFL in South-Carolina and have access to buy all parts available for the various models. We have been trained for maintenance and repair of the 70R 12 fiber ribbon splicer. If you are in Canada with issues with a Fujikura ribbon splicer, get in touch with us and we’ll see if you need to send it to our repair center. If your need is to buy a splicer, please surf Simbol’s website in the fiber splicing section to find the current Fujikura line-up.
Fujikura Fusion Splicer Calibration | Fujikura Repair | FiberOptic Resales
We Only Service U.S. Model Splicers & Cleavers
Please call 877-287-7535 with any questions and we’ll be glad to help.
We pride ourselves on being customer focused to deliver prompt and responsive service.
At FiberOptic Resale our technicians provide calibration & cleaning services to keep your Fujikura fusion splicers and cleavers running like new. Whether you’re having your splicer cleaned & calibrated annually or you’ve put off regular maintenance our techs have the expertise to get you back up and running.
키워드에 대한 정보 fujikura 70r troubleshooting
다음은 Bing에서 fujikura 70r troubleshooting 주제에 대한 검색 결과입니다. 필요한 경우 더 읽을 수 있습니다.
이 기사는 인터넷의 다양한 출처에서 편집되었습니다. 이 기사가 유용했기를 바랍니다. 이 기사가 유용하다고 생각되면 공유하십시오. 매우 감사합니다!
사람들이 주제에 대해 자주 검색하는 키워드 Why Do I Have to Do an Arc Calibration on My Fusion Splicer?
- fusion splicing
- fusion splicer
- arc calibrating
- arc calibration
- electrodes
- electrode power
- singlemode
- fiber
- optical fiber
- fiber optic
- FIS
- Fiber Instrument Sales
- AFL
- CA3
- Fujikura
- fusion splice
- fiber installation
- cable installation
- OS1
- OS2
- simplex
Why #Do #I #Have #to #Do #an #Arc #Calibration #on #My #Fusion #Splicer?
YouTube에서 fujikura 70r troubleshooting 주제의 다른 동영상 보기
주제에 대한 기사를 시청해 주셔서 감사합니다 Why Do I Have to Do an Arc Calibration on My Fusion Splicer? | fujikura 70r troubleshooting, 이 기사가 유용하다고 생각되면 공유하십시오, 매우 감사합니다.